Print Manifest Output


Page started on: Mon Mar 29 10:42:31 EDT 2021
/opt/ignite/bin/print_manifest System Information Your Hewlett-Packard computer has software installed and configured as follows. The system was created April 05, 2013, 03:59:44 EDT. It was created with Ignite-UX revision C.7.0.212. ------------------------------------------------------------- NOTE: You should retain this information for future reference. ------------------------------------------------------------- System Hardware Model: ia64 hp server rx1620 Main Memory: 4076 MB Processors: 2 Intel(R) Itanium 2 processor (1.3 GHz, 3 MB) 1 core, 1 logical processor per socket 400 MT/s bus, CPU version A1 Active processor count: 2 sockets 2 cores OS mode: 64 bit LAN hardware ID: 0x0011855F153A LAN hardware ID: 0x0011855F153B Keyboard Language: USB_PS2_DIN_US_English Storage devices HW Path Interface HP 73.4GMAU3073NC 70007 Mb 64000/0xfa00/0x0 TEAC DV-28E-C 64000/0xfa00/0xf BEECHGLNBGDSAN 921600 Mb 64000/0xfa00/0xe BEECHGLNBGDSAN 921600 Mb 64000/0xfa00/0xd BEECHGLNBGDSAN 1024 Mb 64000/0xfa00/0xc BEECHGLNBGDSAN 1024 Mb 64000/0xfa00/0xb BEECHGLNBGDSAN 1024 Mb 64000/0xfa00/0xa BEECHGLNBGDSAN 204800 Mb 64000/0xfa00/0x9 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x8 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x7 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x6 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x5 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x4 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x3 BEECHGLNBGDSAN 51200 Mb 64000/0xfa00/0x2 HP 73.4GMAU3073NC 70007 Mb 64000/0xfa00/0x1 I/O Interfaces Class H/W Path Driver Description usb 0/0/1/0 hcd NEC OHCI Controller usb 0/0/1/1 hcd NEC OHCI Controller usb 0/0/1/2 ehci NEC EHCI Controller sideba 0/0/2/0 side_multi CMD IDE controller ext_bus 0/0/2/0.0 side IDE Primary Channel ext_bus 0/0/2/0.1 side IDE Secondary Channel ext_bus 0/1/1/0 mpt SCSI Ultra320 ext_bus 0/1/1/1 mpt SCSI Ultra320 lan 0/1/2/0 iether HP PCI-X 1000Base-T Dual-port Built-in lan 0/1/2/1 iether HP PCI-X 1000Base-T Dual-port Built-in fc 0/2/1/0 fcd HP A6826-60001 2Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 1) fc 0/2/1/1 fcd HP A6826-60001 2Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 2) tty 0/4/1/0 asio0 PCI SimpleComm (103c1290) tty 0/4/1/1 asio0 PCI Serial (103c1048) graphics 0/4/2/0 gvid_core PCI Display (10025159) ipmi 250/0 ipmi IPMI Controller tty 250/1 asio0 Built-in RS232C acpi_node 250/2 acpi_node Acpi Hardware escsi_ctlr 64000/0x0/0x0 usb_ms_scsi USB Mass Storage Virt Ctlr Installed Software Your system was installed with HP-UX version B.11.31. Your system has the following software products installed and configured on the system disk drive(s). Product Revision Description 10GigEthr-00 B.11.31.1109 PCI-X 10 Gigabit Ethernet;Supptd HW=AB287, HW=AD385 AccessControl B.11.31.05 HP-UX Role-Based Access Control Infrastructure AppDiscAgent A.7.4.0.92071 Application Discovery Agent B2491BA B.11.31 MirrorDisk/UX (Server) B3701AA C.04.55.00 HP GlancePlus/UX Pak for 11.31 B3835DA C.03.02.02 HP Process Resource Manager B3929EA B.11.31 HP OnLineJFS (Server) B5140BA A.11.31.02 Serviceguard NFS Toolkit B5736DA A.04.20 HA Monitors B6848BA 1.4.gm.46.16 Ximian GNOME 1.4 GTK+ Libraries for HP-UX B8843CA A.03.02.02 HP-UX Workload Manager BG_rx1620a_PB_1131_20150303B.2015.03.03 BG_rx1620a_Patch_Bundle_11.31_2015.03.03 BG_rx1620a_PB_1131_20160126B.2016.01.26 BG_rx1620a_Patch_Bundle_11.31_2016.01.26 BG_rx1620a_PB_1131_20170420B.2017.04.20 BG_rx1620a_Patch_Bundle_11.31_2017.04.20 BG_rx1620a_Patch_Bundle_20150213B.2015.02.13 BG_rx1620a_Patch_Bundle_11.31_2015.02.13 BUNDLE B.2017.05.11 Patch Bundle Base-VXFS B.11.31 Base VxFS File System 4.1 Bundle for HP-UX Base-VXVM B.4.10.032 Base VERITAS Volume Manager Bundle 4.1 for HP-UX BaseLVM B.11.31.1503 Logical Volume Manager CIFS-CLIENT A.02.02.04 HP CIFS Client CIFS-SERVER B.04.12.03.00 HPE CIFS Server CommonIO B.11.31.1503 Common IO Drivers ContainmentExt B.11.31.02 HP-UX Security Containment Extentions DSAUtilities C.01.00.07 HP-UX Distributed Systems Administration Utilities DynRootDisk B.1131.A.3.14.98 Dynamic Root Disk EventMonitoring A.04.20.31.09 Event Monitoring Service FibrChanl-00 B.11.31.1003 FibreChannel;HW=A6795A,A5158A FibrChanl-01 B.11.31.1905 FibrChnl;HW=A6826A,A9782A,A9784A,AB378A/B,AB379A/B,AB465A,AD193A,AD194A,AD300A GigEther-00 B.11.31 PCI GigEther;Supptd HW=A4926A/A4929A/A6096A;SW=J1642AA GigEther-01 B.11.31.1403 PCI GigEther;Supptd HW=A6825A/A6794A/A6847A/A8685A/A9782A/A9784A/A7109A/AB465A HP-UX-PAM-RADIUS A.01.00.00 HP-UX PAM RADIUS HP-UX-SRP A.02.02 HP-UX Secure Resource Partition and Configuration Manager HPSIM-HP-UX C.07.04.00.00.03 HP Systems Insight Manager Server Bundle HPUX-DHCPv4 B.11.31 HPUX DHCPv4 Server HPUX-DHCPv6 B.11.31 HPUX DHCPv6 Server HPUX-FTPServer C.2.6.1.11.0 HPUX FTP Server HPUX-HIDS F.04.08.00 HP-UX Host IDS F.04.08 HPUX-MailServer B.11.31 HPUX Mail Server HPUX-NTP C.4.2.8.0.0 HPUX NTP version 4 HPUX-NameServer B.11.31 HPUX Named Server HPUX-RAMD B.11.31 HPUX IPv6 routing Server HPUX-TCPWRAP B.11.31 HPUX TCPWrapper daemon HPUX11i-OE-MC B.11.31 HP-UX Mission Critical Operating Environment HPUXBastille B.3.0.20 Bastille Security Hardening Tool HPUXEssential B.11.31 Essential HP-UX Utilities HPUXExtns-Jpn B.11.31 Japanese font, input methods and printer extensions HPUXExtns-Kor B.11.31 Korean font, input methods and printer extensions HPUXExtns-SCh B.11.31 Simplified Chinese font, input methods and printer extensions HPUXExtns-TCh B.11.31 Traditional Chinese font, input methods and printer extensions HPUXGatedMrouted B.11.31 HPUX Gated and Mrouted Server HPUXLocales B.11.31 Internationalization Support HPUXMan-Eng B.11.31 Minimum and Essential English man pages HPUXMan-Jpn B.11.31 Minimum and Essential Japanese man pages HPUXMinRuntime B.11.31 Minimum Runtime Environment HPUXMsgs-Fre B.11.31 Minimum and Essential HP-UX French Language Message Catalogs HPUXMsgs-Ger B.11.31 Minimum and Essential HP-UX German Language Message Catalogs HPUXMsgs-Ita B.11.31 Minimum and Essential HP-UX Italian Language Message Catalogs HPUXMsgs-Jpn B.11.31 Minimum and Essential HP-UX Japanese Language Message Catalogs HPUXMsgs-Kor B.11.31 Minimum and Essential HP-UX Korean Language Message Catalogs HPUXMsgs-SCh B.11.31 Minimum and Essential HP-UX Simplified Chinese Language Message Catalogs HPUXMsgs-Spa B.11.31 Minimum and Essential HP-UX Spanish Language Message Catalogs HPUXMsgs-Swe B.11.31 Minimum and Essential HP-UX Swedish Language Message Catalogs HPUXMsgs-TCh B.11.31 Minimum and Essential HP-UX Traditional Chinese Language Message Catalogs IEther-00 B.11.31.1806 PCI/PCI-X/PCIe IEther IGNITE C.7.18.63 HP-UX Installation Utilities (Ignite-UX) IPFilter A.11.31.18.25 HP IPFilter 3.5alpha5 ISOIMAGE-ENH B.11.31.06 ISO Image mount Enhancement Ignite-UX-11-31 C.7.18.63 HP-UX Installation Utilities for Installing 11.31 Systems JAVAOOB 2.06.00 Java2 Out-of-box for HP-UX Java15JDK 1.5.0.03.05 Java 1.5 JDK for HP-UX Java15JRE 1.5.0.30.00 Java 1.5 JRE for HP-UX Java60JRE 1.6.0.22.00 Java 6.0 JRE for HP-UX KRB5CLIENT E.1.6.2.10 Kerberos V5 Client Version 1.6.2.10 LDAPUX B.05.03 LDAP-UX Integration MOZILLA 1.7.13.01.01 Mozilla for HP-UX MOZILLAsrc 1.7.13.01.01 Mozilla Source distribution MgdSysSetupWzrd A.7.4.0.2939 Insight managed system setup wizard NParCmds B.11.31.1303 NPartition Commands ONCplus B.11.31.22 ONC+ 2.3 OVsnmpAgent C.17.3.4 HP-UX Emanate SNMP Agent OpenSSL A.01.01.01d.001 Secure Network Communications Protocol PAMKerberos D.01.26 PAM-Kerberos Version 1.26 PAX-ENH B.11.31.16 PAX_Enh enhancement to support backup of more number of directories PRMKernelSW C.03.02.02 HP PRM Kernel Software PRMLibraries C.03.02.02 HP PRM Software Libraries PRMSIMTools C.03.06 HP PRM Web GUI SIM Integration Files ParMgr B.31.02.03.01 Partition Manager - HP-UX QPKAPPS B.11.31.2009.447c Applications Patches for HP-UX 11i v3, Sep 2020 QPKBASE B.11.31.2009.447c Base Quality Pack Bundle for HP-UX 11i v3, Sep 2020 RAID-01 B.11.31.1910 RAID SA; Supptd HW=A7143A/A9890A/A9891A SATADVD-00 B.11.31.1805 PCIe SATA DVD Driver SD B.11.31.1403.401 HP Software Distributor Sec00Tools B.01.04.07 Install-Time security infrastructure. SecPatchCk B.02.05 HP-UX Security Patch Check Tool SecureShell A.08.10.003 HP-UX Secure Shell SerialSCSI-00 B.11.31.1303 PCI-X/PCI-E SerialSCSI SwMgmtMin B.11.31.01 HP-UX Software Management Tools SysMgmtMin B.11.31 Minimum Software Deployment Tools SysMgmtPlus A.10.00.03.01 HP-UX SMH Supplemental Functionality SysMgmtWeb A.3.2.20.04 HP-UX Web Based System Management User Interfaces T1456AA 1.4.2.10.08 Java2 1.4 SDK for HP-UX T1457AA 1.4.2.10.08 Java2 1.4 RTE for HP-UX T1458AA 1.4.2.10.08 Java2 1.4 Netscape Plugin for HP-UX T1905CA A.11.17.01 Serviceguard T1909BA B.04.00 Enterprise Cluster Master Toolkit USB-00 D.11.31.0903.01 Transition USB-00 Product UtilProvider A.01.08.13.00 HP-UX Utilization Provider VMGuestLib A.02.00.31 Integrity VM Guest Support Libraries VMProvider A.02.00.31 WBEM Provider for Integrity VM VRTSvxfs_5_0_1_PB_1131_20160226B.2016.02.26 VRTSvxfs_5_0_1_Patch_Bundle_11.31_2016.02.26 VSEMgmt A.7.4.0.92225 HP Insight Dynamics - VSE Suite for Integrity VseAssist A.7.4.0.92204 Virtual Server Environment Configuration Assistant WBEMMgmtBundle C.18.01 WBEMMgmtBundle WLMToolkits A.01.10.01 HP-UX Workload Manager Toolkits gWLMAgent A.7.4.0.92225 HP Global Workload Manager Agent hpuxws22Apache B.2.2.29.04 HP-UX Apache-based Web Server hpuxws22Tomcat D.7.0.68.01 HP-UX Tomcat-based Servlet Engine hpuxws22Webmin A.1.070.13 HP-UX Webmin-based Admin hpuxws24Apache B.2.4.18.03 HP-UX Apache-based Web Server hpuxws24Tomcat D.7.0.84.01 HP-UX Tomcat-based Servlet Engine hpuxws24Webmin B.1.070.14 HP-UX Webmin-based Admin hpuxwsApache B.2.0.64.01 HPUX Apache Web Server hpuxwsTomcat B.5.5.30.04 HP-UX Tomcat-based Servlet Engine hpuxwsWebmin A.1.070.10 HPUX Webmin hpuxwsXml A.2.01 HPUX XML ixNet-SNMP A.19.00-5.6.1.1.001Simple Network Monitoring protocol ixPython A.21.00-2.7.13.001A Sophisticated, New, Interpreted OOP Language ixSudo A.20.00-1.8.6p3.001Super User Do perl E.5.8.8.M Perl Programming Language perl528 E.5.28.0.A Perl Programming Language rx1620a_PB_1131_20210326B.2021.03.26 rx1620a_Patch_Bundle_11.31_2021.03.26 scsiU320-00 B.11.31.1805 PCI-X SCSI U320;Supptd HW=A7173A/AB290A HPOvLcore 6.00.000 HP Software Core Functionality HPOvPerf 4.70.000 HP OpenView Performance PHCO_36480 1.0 userdb cumulative patch PHCO_39064 1.0 FirstBoot sysinfo.4 manpage patch PHCO_41195 1.0 VRTS 4.1 GARP5 VRTSvxvm Command Patch PHKL_40536 1.0 VRTS 4.1 GARP4 VRTSvxvm kernel Patch PHKL_41418 1.0 fs_mnttab cumulative patch SysMgmtHomepage A.3.2.9 HP-UX System Management Homepage - Web-Based User Interfaces gcc 4.7.2 gcc lsof 4.87 lsof LVM File System Configuration This system is configured with Logical Volume Manager (LVM) file systems. Refer to the File System layout section for information on the LVM layout. JFS File System Configuration This system is configured with a Journaled File System (referred to as either JFS or VXFS). Refer to the File System layout section for information on JFS/VXFS file systems. Disk layout File System layout LVM Device file mount point size fs type /dev/vg00: /dev/vg00/lvol1 /stand 1792 vxfs /dev/vg00/lvol2 swap 8192 /dev/vg00/lvol3 / 1024 vxfs /dev/vg00/mark /var/opt/ignite 51200 vxfs /dev/vg00/lvol4 /tmp 20032 vxfs /dev/vg00/lvol5 /home 256 vxfs /dev/vg00/lvol6 /opt 8064 vxfs /dev/vg00/lvol7 /usr 5376 vxfs /dev/vg00/lvol8 /var 26688 vxfs /dev/vg00 unallocated 81216 Swap configuration type size priority device/location dev 8192 1 /dev/vg00/lvol2 Kernel Configuration The following drivers or parameters are configured into your system's kernel. After installing HP-UX, use the sam(1m) command to configure the following items into the kernel: cmpt_fs_enhs 1 cmpt_net_enhs 3 maxdsiz 2147483648 max_thread_proc 3000 audit_track_paths 1 System Information The following parameters were set on the configured target: hostname: rx1620a IP address: 10.42.28.75 subnet mask: 0xffffff00 gateway IP address: 10.42.28.1 time zone: EST5EDT DNS domain name: beechglen.com DNS IP address: 192.168.88.53 DNS IP address: 192.168.88.49
Page completed on: Mon Mar 29 10:42:32 EDT 2021